industry news
Subscribe Now

Rohde & Schwarz adds six new probe models to its power electronics measurement portfolio

The new R&S RT-ZHD high voltage differential probes are designed for complex measurements on state-of-the-art power electronics with voltages up to 6000 V. They offer a measurement bandwidth of up to 200 MHz, a particularly high common mode rejection ratio (CMRR) and at 0.5 percent, the best DC measurement accuracy available. Rohde & Schwarz also presents cost-efficient, high voltage differential probes with a 25 MHz bandwidth and very low inherent noise – ideal for general applications.

Munich, January 23, 2018 — Demand in the automotive industry for compact, highly efficient switched-mode power supplies, inverters and electric drives necessitates the use of leading-edge semiconductor components. This creates new challenges for T&M equipment. The new high voltage differential probes from Rohde & Schwarz enable measurements with outstanding signal integrity and are perfect for use with the new R&S RTM3000 and R&S RTA4000 embedded oscilloscopes.

200 MHz measurement bandwidth and excellent common mode rejection

The new R&S RT-ZHD high voltage differential probes are ideal for measurements on modern power semiconductors. With a bandwidth of up to 200 MHz, they can even measure very fast switching edges. The excellent common mode rejection across the entire frequency range effectively suppresses fast-switching common mode signals. There are four different models with maximum peak voltages from 750 V to 6000 V.

Up to 2000 V offset compensation

The integrated offset compensation operates independently of probe attenuation and the oscilloscope’s vertical settings. This makes it possible to measure even very small ripple voltages with a large DC component. Thanks to an offset compensation of up to 2000 V, the R&S RT-ZHD probes cover a very large range of measurement applications.

Highest DC measuring accuracy

At ± 0.5 percent, the R&S RT-ZHD high-voltage differential probes have the best DC measuring accuracy on the market. The probes also feature an integrated R&S ProbeMeter that measures DC offset with ± 0.1 percent accuracy. The readings are displayed directly on the oscilloscope.

Full integration eliminates Errors

Complete integration of the R&S RT-ZHD probes into the user interface of Rohde & Schwarz oscilloscopes eliminates erroneous readings. The oscilloscopes automatically recognize the configured attenuation factor as well as all other probe settings, so they always display the correct voltages and reliably detect incidents such as overvoltage. Probe functions can also be accessed via the SCPI remote control interface, making the probes a good choice for automated tests. The R&S RT-ZHD probes are compatible with both the new R&S RTM3000 and R&S RTA4000 embedded oscilloscopes as well as the Windows-based R&S RTE1000 and R&S RTO2000 oscilloscopes.

R&S RT-ZD002/-ZD003: when 25 MHz bandwidth is sufficient

Two other new additions are the R&S RT-ZD002 and R&S RT-ZD003 differential probes with maximum input voltages up to 700 V and 1400 V, respectively. These 25 MHz probes boast very low inherent noise for their class of around 7 mV (RMS) and 14 mV (RMS), respectively. Their BNC interface makes them a perfect fit for R&S RTC1000, R&S RTB2000 and all standard oscilloscopes.

High-performance portfolio for power electronics measurements

These new probes enhance the Rohde & Schwarz portfolio for power electronics measurements. The new R&S RT-ZHD and R&S RT-ZD002/-ZD003 high voltage differential probes are now available from Rohde & Schwarz. For more information, visit www.rohde-schwarz.com/ad/press/probesportfolio.

Leave a Reply

featured blogs
Apr 25, 2024
Structures in Allegro X layout editors let you create reusable building blocks for your PCBs, saving you time and ensuring consistency. What are Structures? Structures are pre-defined groups of design objects, such as vias, connecting lines (clines), and shapes. You can combi...
Apr 25, 2024
See how the UCIe protocol creates multi-die chips by connecting chiplets from different vendors and nodes, and learn about the role of IP and specifications.The post Want to Mix and Match Dies in a Single Package? UCIe Can Get You There appeared first on Chip Design....
Apr 18, 2024
Are you ready for a revolution in robotic technology (as opposed to a robotic revolution, of course)?...

featured video

How MediaTek Optimizes SI Design with Cadence Optimality Explorer and Clarity 3D Solver

Sponsored by Cadence Design Systems

In the era of 5G/6G communication, signal integrity (SI) design considerations are important in high-speed interface design. MediaTek’s design process usually relies on human intuition, but with Cadence’s Optimality Intelligent System Explorer and Clarity 3D Solver, they’ve increased design productivity by 75X. The Optimality Explorer’s AI technology not only improves productivity, but also provides helpful insights and answers.

Learn how MediaTek uses Cadence tools in SI design

featured paper

Designing Robust 5G Power Amplifiers for the Real World

Sponsored by Keysight

Simulating 5G power amplifier (PA) designs at the component and system levels with authentic modulation and high-fidelity behavioral models increases predictability, lowers risk, and shrinks schedules. Simulation software enables multi-technology layout and multi-domain analysis, evaluating the impacts of 5G PA design choices while delivering accurate results in a single virtual workspace. This application note delves into how authentic modulation enhances predictability and performance in 5G millimeter-wave systems.

Download now to revolutionize your design process.

featured chalk talk

It’s the little things that get you; Light to Voltage Converters
In this episode of Chalk Talk, Amelia Dalton and Ed Mullins from Analog Devices chat about the what, where, and how of photodiode amplifiers. They discuss the challenges involved in designing these kinds of components, the best practices for analyzing the stability of photodiode amplifiers, and how Analog Devices can help you with your next photodiode amplifier design.
Apr 22, 2024