industry news
Subscribe Now

Renesas Electronics Introduces RX Functional Safety Solution with World’s First SIL3 Software Certification for Industrial Equipment

Provides Complete Industrial Functional Safety Support, Including Mutual Fault Diagnosis for Dual-Microcontroller Structure and Function that Isolates Multiple Software Applications

Düsseldorf, March 7, 2019 – Renesas Electronics Corporation (TSE: 6723), a premier supplier of advanced semiconductor solutions, today announced the new “RX Functional Safety” solution for industrial applications that reduces the complexity of IEC 61508 SIL3 (Note 1) certification, an international standard for functional safety. Based on the RX family of microcontrollers (MCUs), the new solution provides advanced functional safety for industrial equipment, including functions for chip self-diagnostics, the world’s first (Note 2) SIL3-certified functional safety software and reference documents for users to develop the safety part of industrial applications. The complete functional safety support for industrial applications allows users to shorten the certification acquisition process by a year or more.

Featuring a dual-MCU configuration, the RX Functional Safety will support all Renesas MCUs based on the RXv2 core to enable simple safety verification and a highly efficient diagnostics software. With the SIL3-certified software, the solution eliminates the need for users to develop functional safety software dependant to Renesas MCUs and allows them to focus on development of software for their own application components.

“The need for functional safety is expanding to an ever wider variety of products, driving increased needs for shorter development times and lower costs,” said Masataka Nakao, Manager, Functional Safety Industrial Service Division, at TÜV Rheinland Japan. “The Renesas solution that we have now certified provides both the diagnostic functions required in a functional safety MCU and the functions that make it easy to reuse software assets. We expect that the solution will allow both customers new to developing functional safety products, and customers with functional safety experience to improve their development efficiency.”

“As robot-human interaction in industrial environments becomes more common, we have seen many customers struggling with the complex and often time-consuming challenge of functional safety, which is becoming a significant barrier for the industry,” said Akira Denda, Vice President, Industrial Automation Business Division, Renesas Electronics Corporation. “We are confident that our new RX Functional Safety will contribute to saving their time and resources and can dramatically accelerate the broad adoption of industrial equipment supporting functional safety.”

When starting on a new functional safety system, developers face a large number of difficult technological problems, including the interpretation of difficult standards, acquiring methods for constructing dual-structure MCUs, and selecting third parties for support. Users experienced in configuring functional safety systems are also challenged with development burdens such as acquiring software certification and the recertification associated with the expansion of system functions.

To resolve these issues, Renesas has developed a comprehensive, software -based solution combining:

  • RX Functional Safety – Self-Test Software Kit: Performs self-diagnostics at the individual MCU level
  • Self-diagnostics software library*
  • Safety manual*
  • User guide*

Asterisks (*) indicate items that have received IEC 61508 SIL3 certification from TÜV Rheinland

    • RX Functional Safety – SIL3 System Software Kit: Achieves the world’s first SIL3 certification by performing required mutual diagnostics in a dual MCU architecture structure and a function that isolates multiple software applications to implement functional safety.
  • Functional safety platform software*
  • Safety manual*
  • User guide*
  • IEC 61508 SIL3 certification documents (certification document, test report)
  • Software development handbook
  • Configuration tool for generating and evaluating configuration files that set up the functional safety platform software and set user application behaviour
  • Configuration tool manual

Asterisks (*) indicate items that have received IEC 61508 SIL3 certification from TÜV Rheinland.

  • RX Functional Safety – Reference Hardware: Dual-structure MCU evaluation board using the RX71M and RX651 MCUs, and related technical documentation (manuals, circuit diagrams, parts lists, and other items)
  • RX Functional Safety – Reference Documents: Technical documentation to help developers acquire SIL3 certification for their applications.

About the RX Functional Safety – SIL3 System Software Kit

The new solution features the first SIL3-certified software that includes mutual diagnosis that presupposes a dual MCU structure and software isolation functions (safe and non-safe isolation functions) that isolate multiple application software programs from affecting each other. In situations where software changes occur in association with deployment to multiple versions, the software isolation function allows certification of only the software sections that have changed. This can significantly reduce the time required for recertification application and certification application itself, reducing the burdens involved in developing dual-MCU configuration systems.

Application software not related to functional safety – such as the system control software and safety monitoring software – can be embedded in a single MCU using the software isolation function, minimizing the need for additional devices for safety monitoring.

Availability

All four elements of the RX Functional Safety are available now. To reduce developers’ initial costs and conduct trials, Renesas will also provide a free version of the RX Functional Safety – Self-Test Software Kit and a free evaluation version of the RX Functional Safety – SIL3 System Software Kit. (Availability subject to change.)

For more information on the RX Functional Safety, please visit: https://www.renesas.com/solutions/industrial-automation/functional-safety/functional-safety-solution-for-industrial-automation.html

(Note 1) Safety Integrity Level (SIL) is a measure of risk reduction. IEC61508 defines the levels from 1 to 4, with 4 providing the highest level of safety integrity and 1 the lowest level.

(Note 2) Renesas source as of March 7, 2019.

About Renesas Electronics Corporation

Renesas Electronics Corporation (TSE: 6723) delivers trusted embedded design innovation with complete semiconductor solutions that enable billions of connected, intelligent devices to enhance the way people work and live. A global leader in microcontrollers, analog, power, and SoC products, Renesas provides comprehensive solutions for a broad range of automotive, industrial, home electronics, office automation, and information communication technology applications that help shape a limitless future. Learn more at renesas.com.

Leave a Reply

featured blogs
Apr 25, 2024
Structures in Allegro X layout editors let you create reusable building blocks for your PCBs, saving you time and ensuring consistency. What are Structures? Structures are pre-defined groups of design objects, such as vias, connecting lines (clines), and shapes. You can combi...
Apr 25, 2024
See how the UCIe protocol creates multi-die chips by connecting chiplets from different vendors and nodes, and learn about the role of IP and specifications.The post Want to Mix and Match Dies in a Single Package? UCIe Can Get You There appeared first on Chip Design....
Apr 18, 2024
Are you ready for a revolution in robotic technology (as opposed to a robotic revolution, of course)?...

featured video

How MediaTek Optimizes SI Design with Cadence Optimality Explorer and Clarity 3D Solver

Sponsored by Cadence Design Systems

In the era of 5G/6G communication, signal integrity (SI) design considerations are important in high-speed interface design. MediaTek’s design process usually relies on human intuition, but with Cadence’s Optimality Intelligent System Explorer and Clarity 3D Solver, they’ve increased design productivity by 75X. The Optimality Explorer’s AI technology not only improves productivity, but also provides helpful insights and answers.

Learn how MediaTek uses Cadence tools in SI design

featured paper

Designing Robust 5G Power Amplifiers for the Real World

Sponsored by Keysight

Simulating 5G power amplifier (PA) designs at the component and system levels with authentic modulation and high-fidelity behavioral models increases predictability, lowers risk, and shrinks schedules. Simulation software enables multi-technology layout and multi-domain analysis, evaluating the impacts of 5G PA design choices while delivering accurate results in a single virtual workspace. This application note delves into how authentic modulation enhances predictability and performance in 5G millimeter-wave systems.

Download now to revolutionize your design process.

featured chalk talk

Dependable Power Distribution: Supporting Fail Operational and Highly Available Systems
Sponsored by Infineon
Megatrends in automotive designs have heavily influenced the requirements needed for vehicle architectures and power distribution systems. In this episode of Chalk Talk, Amelia Dalton and Robert Pizuti from Infineon investigate the trends and new use cases required for dependable power systems and how Infineon is advancing innovation in automotive designs with their EiceDRIVER and PROFET devices.
Dec 7, 2023
18,225 views