Tests show accurate operation can be sustained at mK temperature levels while simultaneously exposed to ultra-strong magnetic fields.

12 May 2021, Cambridge, UK: Paragraf continues to push performance boundaries with its graphene Hall Effect sensors. Oxford Instruments, a leading provider of high technology tools and systems for research and industry, have employed a modified version of the Paragraf GHS09CC sensor device to carry out measurements at temperatures and magnetic field strengths far beyond the scope of any other sensing solution.

The test set-up saw the modified Paragraf GHS09CC device exposed to a 14T magnetic field. This was applied via an Oxford Instruments’ superconducting solenoid magnet. The temperature level was taken down below 100mK, using the newly released Proteox dilution refrigerator.

Normally under these harsh operating conditions, acquisition of field strength data would be impossible. The low temperatures involved would lead to quantum effects that would saturate the sensor. Even before reaching these extremes, other anomalies would impact upon sensor linearity, thereby making accurate measurements very difficult to achieve.

As Ellie Galanis, Product Owner at Paragraf, explains: “Though there are huge opportunities to carry out fundamental research at these temperature levels, Hall Effect sensors have not been able to offer mK operation until now. The tests conducted by Oxford Instruments underline the quality of the graphene substrates we can fabricate for cutting-edge electronic systems, as well as our innate ability to tailor them as customer requirements dictate. There is no other cryogenic temperature Hall Effect sensor that is rated to these operational parameters, showing that we can really differentiate ourselves here.”

“High-resolution field measurement at ultralow temperatures and high magnetic fields has always been a challenge” adds Benjamin Bryant, Senior Development Engineer at Oxford Instruments. “Conventional Hall sensors can suffer carrier freeze-out at mK temperatures, and even if they could still function their heat dissipation is much too high. Graphene sensors give us and our customers the opportunity, for the first time, to monitor high magnetic fields in-situ in ultra-low temperature experiments.”

High energy physics labs and other fundamental research establishments have previously had to rely on off the shelf cryo-rated Hall sensors (rated to 1.5K at the lowest) or expensive custom NMR probes. These generate a considerable amount of heat, and this has a detrimental influence on the ability to maintain a mK environment and therefore the results obtained.

In contrast, the Paragraf sensor generates 6 orders of magnitude less heat (dissipating nW rather than mW figures). Through optimisation of the constituent graphene, it can support linear operation – presenting customers with a ground-breaking sensing solution that is unmatched in terms of performance, data reproducibility and ease of calibration.

The Oxford Instruments Proteox dilution refrigerator was pivotal in these tests. It has the capacity to support precisely controlled temperatures over an expansive 10 mK to 30K range, even when subjected to very high magnetic fields. Competing dilution fridges, by comparison, can only cope with much narrower temperature ranges. It provides a flexible platform for addressing the scaling up of advanced quantum hardware solutions.

Paragraf’s mK capable sensors will pave the way for more advanced scientific instruments, with Oxford Instruments set to become one of the first customers in this exciting new area.

Leave a Reply

featured blogs
Apr 18, 2024
Are you ready for a revolution in robotic technology (as opposed to a robotic revolution, of course)?...
Apr 18, 2024
See how Cisco accelerates library characterization and chip design with our cloud EDA tools, scaling access to SoC validation solutions and compute services.The post Cisco Accelerates Project Schedule by 66% Using Synopsys Cloud appeared first on Chip Design....
Apr 18, 2024
Analog Behavioral Modeling involves creating models that mimic a desired external circuit behavior at a block level rather than simply reproducing individual transistor characteristics. One of the significant benefits of using models is that they reduce the simulation time. V...

featured video

MaxLinear Integrates Analog & Digital Design in One Chip with Cadence 3D Solvers

Sponsored by Cadence Design Systems

MaxLinear has the unique capability of integrating analog and digital design on the same chip. Because of this, the team developed some interesting technology in the communication space. In the optical infrastructure domain, they created the first fully integrated 5nm CMOS PAM4 DSP. All their products solve critical communication and high-frequency analysis challenges.

Learn more about how MaxLinear is using Cadence’s Clarity 3D Solver and EMX Planar 3D Solver in their design process.

featured chalk talk

Using the Vishay IHLE® to Mitigate Radiated EMI
Sponsored by Mouser Electronics and Vishay
EMI mitigation is an important design concern for a lot of different electronic systems designs. In this episode of Chalk Talk, Amelia Dalton and Tim Shafer from Vishay explore how Vishay’s IHLE power inductors can reduce radiated EMI. They also examine how the composition of these inductors can support the mitigation of EMI and how you can get started using Vishay’s IHLE® High Current Inductors in your next design.
Dec 4, 2023
18,528 views